EasyManua.ls Logo

Nordson Spectra 30 - Pressure Run-Up

Nordson Spectra 30
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using the Menus
5-17
Part 1124631_01
E 2015 Nordson Corporation
Pressure Run-up
Use this screen to set the two-point linear pressure curve. This setting allows
the pattern controller to accurately regulate the system pressure to maintain
proper adhesive volume during line speed changes.
1
2
8
4
6
7
3
5
9
Figure 5-14 Pressure Run up menu
1.MaximumLinePressure(percent)
2. Pressure Setting in percent for
end points (items 5 or 6 in
Figure 5-14)
3. Pressure point setting
Increase/Decrease
4. Minimum Pressure (percent)
5. Set point 1 (unselected)
6. Set point 2 (selected)
7. Display graph
8. Line speed for corresponding
pressure point setting
(items 5 or 6 in Figure 5-14)
9. Set line
1. Tap Maximum Line Pressure to open the numeric keypad, assign the
maximum pressure cutoff limit.
2. Tap Minimum Line Pressure to open the numeric keypad to set the
minimum line pressure cutoff limit.
NOTE: The relationship of the pressure output and the line speed
appears in the display graph.
3. Select upper pressure point (see item 5 in Figure 5-14) and enter
pressure (%) at the corresponding line speed.
4. If a lower pressure point is desired, tap a lower pressure point (see item 6
in Figure 5-14) and enter pressure and line speed in percent.

Table of Contents