TheUserInterface
4-36
Part 1124631_01
E 2015 Nordson Corporation
Setting the Applicators (contd)
Use the following components to assign or modify the applicator settings:
SeeFigure4-31fortheapplicatorscreencomponents.
Tap Action
(Item 1 in
Figure 4-31)
Select a pattern type from the available list:
S Normal
S Dot
S EcoBead
S Random length
S Mirror
Optional Patterns
S Random dotted
S Autodot
S Continuous
For details refer to Pattern Programming, given earlier.
(Item 2 in
Figure 4-31)
Select the next trigger (1- 4) for triggering the applicator.
Only installed triggers are selectable.
(Item 8 in
Figure 4-31)
Select an applicator channel (1 - 4).
Only installed applicators are selectable.
(Item 5 in
Figure 4-31)
100
Use the numeric keypad to enter gun-to-trigger offset
(GTO).
NOTE: GTO is the distance from the center line of the
gun nozzle to the center line of the trigger lens.
Continued...