EasyManua.ls Logo

Oceanic versa Pro - SPECIFICATIONS

Oceanic versa Pro
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88
DISPLAY RANGE/RESOLUTION (continued)
Numeric Displays: Range: Resolution:
Time to Fly 23:50 - 0:00 hr:min* 1 minute
(* starting 10 min after the dive)
Time to Desaturate 23:50 (maximum) - 0:00 hr:min* 1 minute
(* starting 10 min. after the dive)
Temperature 0 to 99°F (-9 to 60°C)
Special Displays: Occurrence
Diagnostic Display After Manual Activation
Out of Range (- - -) >330 feet (>99.9 meters)
Gauge Mode Countdown Timer 23:50 to 0:00 hr:min (after violation)
BAR GRAPHS
Tissue Loading Bar Graph segments Oxygen (O2) Bar Graph: segments
No Decompression zone (green) 5 Normal zone (green) 3
No Deco Caution zone (yellow) 2 Caution zone (yellow) 1
Decompression Warning zone (red) 1 Danger zone (red) 1
Variable Ascent Rate Indicator: 60 feet (18 m) & Shallower Deeper than 60 feet (18 m)
segments feet/min meters/min segments feet/min meters/min
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal Zone (Green) 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal Zone (Green) 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal Zone (Green) 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
Caution Zone (Yellow) 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast Zone (Red - flashing) 5 > 30 > 9 5 > 60 > 18