45641001TH Rev.1
8-7/
Oki Data CONFIDENTIAL
Notes:
• Thedisplayofitemsonthisscreenvariesdependingonthetypesofdatawritten
on the USB device.
Each item is displayed only when each data file is written on the USB device in
the following conditions.
Item Condition
1.SYSTEMFIRMWARE
(OS Data)
O290SF0Wxxxx.tariswritten.(xxxxisversion.)
2.ENGINEFIRMWARE H291PUPWW.xxxxiswritten.(xxxxisversion.)
3.SCANNERFIRMWARE H282SUPWW.xxxxiswritten.(xxxxisversion.)
4.SYSTEMSOFTWARE
(HD Data)
O290HD0Wxxxx.tariswritten.(xxxxisversion.)
• IftheUSBdeviceisnotrecognizedproperly,“USBdeviceNotdetected”message
isdisplayed.Inthiscase,disconnecttheUSBdeviceandconnectagainwithin
3minutes,orshutdowntheequipmentandconnectthedeviceproperly.Then
repeat the procedure from (4).
• Ifanyoftheerrormessagesbelowisdisplayed,conrmifthedataleintheUSB
device is correct.
Then repeat the procedure from (4).
Error
number
Error message Cause
01 ErrorLoadmodule Module loading failed.
02 Machine Model Get Error Model information was
not downloaded.
03 Copy Data with valid signature in USB Storage Checking of data file
failed.
04 OthermodelsROMDATATXXXXXXXX
*Theversionnamecomesat“xxxx.xxx.x”.
Master data of other
model are stored.
05 Copy Signature File in USB Storage Data files are not
stored in the USB
device.
06 Patch and Normal package in one folder
of USB Storage
Whenboththesystem
and patch update
packages are in the
USB device
(6) Select the item with the digital keys.
“*”isdisplayednexttotheselecteditem.Displayordeletethe“*”bypressingthe
number of the item.
Item Remarks
1.SYSTEMFIRMWARE(OSData) Updating System firmware
2.ENGINEFIRMWARE Updating PU firmware
3.SCANNERFIRMWARE Updating SU firmware
4.SYSTEMSOFTWARE(HDData) Updating System software