Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System General 9103 Time differences Refer to
contents
0-47 SYS 0: +12.0h 1: +11.5h 2: +11.0h 3: +10.5h 4: +10.0h
5:+9.5h6:+9.0h7:+8.5h8:+8.0h9:+7.5h
10: +7.0h 11: +6.5h 12: +6.0h 13: +5.5h 14: +5.0h
15:+4.5h16:+4.0h17:+3.5h18:+3.0h19:+2.5h
20: +2.0h 21: +1.5h 22: +1.0h 23: +0.5h 24: 0.0h
25:-0.5h26:-1.0h27:-1.5h28:-2.0h29:-2.5h
30: -3.0h 31: -3.5h 32: -4.0h 33: -4.5h 34: -5.0h
35:-5.5h36:-6.0h37:-6.5h38:-7.0h39:-7.5h
40:-8.0h41:-8.5h42:-9.0h43:-9.5h44:-10.0h
45: -10.5h 46: -11.0h 47: -11.5h
<Default value>
ODA: 40
JP: 6
Others: 24
1
08 Setting
mode
System User
interface
9110 Auto-clear timer
setting
3 0-10 SYS Timertoreturntheequipmenttothedefaultsettingswhen
the [START] button is not pressed after the function and
the mode are set
0: Not cleared
1 to 10: Set number x 15 sec.
1
08 Setting
Mode
System User
interface
9111 Power save mode
timer setting
4 0,4,6-15 SYS Timer to automatically switch to the auto power save
modewhentheequipmenthasnotbeenused
0: Invalid
4: 1 min.
6: 3 min.
7: 4 min.
8:5min.
9: 7 min.
10: 10 min.
11: 15 min.
12: 20 min.
13: 30 min.
14: 45 min.
15: 60 min.
1
08 Setting
Mode
System User
interface
9112 Shut Off
timer
setting (Sleep
Mode)
21 0-21 SYS Timer to automatically switch to the auto sleep mode
whentheequipmenthasnotbeenused
0: 3 min. 1: 5 min. 2: 10 min.
3: 15 min. 4: 20 min. 5: 25 min.
6:30min. 7:40min. 8:50min.
9:60min. 10:70min. 11:80min.
12: 90 min. 13: 100 min. 14: 110 min.
15:120min. 16:150min. 17:180min.
18:210min. 19:240min. 20:Invalid
21: 1 min.
1