45641001TH Rev.1
11-56 /
Oki Data CONFIDENTIAL
05/
08
Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System 9060 Destination
display at SRAM
initialization
Refer to
contents
0-255 SYS 20:ODA(ODC-IT)21:OEL(ODC-IT)
22: AOS (ODC- IT) 23: JP (ODC-IT) 30: ODA (ODC-OA)
31:OEL(ODC-OA)32:AOS(ODC-OA)
33: JP (ODC-OA)
<Default value>
ODA:20OEL:21AOS:22JP:23
*Whenthedefaultvalueof08-9845is“0”,thedefaultvalue
ofthiscodeis“ODA:30OEL:31AOS:32JP:33”.
2
08 Setting
Mode
System HDD 9065 HDD diagnostic
menu display
- - SYS Displays the HDD information. 2
08 Setting
Mode
System HDD 9072 Performing HDD
testing
- - SYS Checks the bad sector. It may take more than 30 minutes
to finish the checking.
3
08 Setting
mode
System General 9081 Initialization
of department
management
information
- - SYS Initializing of the department management information
Enter the code with the digital keys and press the
[INITIALIZE]buttontoperformtheinitialization.
If the area storing the department management
informationisdestroyedforsomereason,“Enter
Department Code” is displayed on the control panel even
if the department management function is not set on. In
thiscase,initializetheareawiththiscode.Thisareais
normally initialized at the factory.
3
08 Setting
Mode
System Initialization 9083 Initialization of NIC
information
- - SYS Returns the value to the factory shipping default value. 3
08 Setting
mode
System General 9100 Date and time
setting
- 13 digits - Year/month/date/day/hour/minute/second
Example:
0307013132748
“Day”-“0”isfor“Sunday”.ProceedsMondaythrough
Saturdayfrom“1”to“6”.
5
08 Setting
mode
System User
interface
9102 Date display format Refer to
contents
0-2 SYS 0: YYYY.MM.DD
1: DD.MM.YYYY
2: MM.DD.YYYY
<Default value>
ODA: 2
JP: 0
Others: 1
1