45641001TH  Rev.1 
v / 
Oki  Data  CONFIDENTIAL
2.  General Precautions at Service
-  Be sure to turn the power OFF and unplug the power cable during service (except for the 
service should be done with the power turned ON).
-  Unplug the power cable and clean the area around the prongs of the plug and socket outlet 
once a year or more. A fire may occur when dust lies on this area.
- Whenthepartsaredisassembled,reassemblyisthereverse ofdisassemblyunless
otherwise noted in this manual or other related documents. Be careful not to install small 
partssuchasscrews,washers,pins,E-rings,starwashers,harnessesinthewrongplaces.
- Basically,theequipmentshouldnotbeoperatedwithanypartsremovedordisassembled.
- The PC board must be stored in an anti-electrostatic bag and handled carefully using a 
antistatic wrist strap since the ICs on it may be damaged due to static electricity.
Caution: Beforeusingtheantistaticwriststrap,unplugthepowercableoftheequipment
andmakesurethattherearenochargedobjectswhicharenotinsulatedinthe
vicinity.
-  Be sure not to touch high-temperature sections such as the fuser unit and areas around 
them.
- Besurenottotouchhigh-voltagesectionssuchasthechargers,transferbelt,developer,
high-voltagetransformer,andpowersupplyunit.Especially,theboardofthese
componentsshouldnotbetouchedsincetheelectricchargemayremaininthecapacitors,
etc. on them even after the power is turned OFF.
- Makesurethattheequipmentwillnotoperatebeforetouchingpotentiallydangerousplaces
(e.g.rotating/operatingsectionssuchasgears,beltspulleys,andfans).
-  Be careful when removing the covers since there might be the parts with very sharp edges 
underneath.
- WhenservicingtheequipmentwiththepowerturnedON,besurenottotouchlivesections
and rotating/operating sections.
- Usedesignatedjigsandtools.
- Userecommendedmeasuringinstrumentsorequivalents.
- Return the equipment to the original state and checkthe operation when the service is
finished.
-  Be very careful to treat the touch panel gently and never hit it. Breaking the surface could 
cause malfunctions.
3.  Important Service Parts for Safety
- The door switch,fuse, thermostat, thermofuse,thermistor,batteries,IC-RAMsincluding
lithium batteries, etc. are particularly important for safety. Be sure to handle/install them
properly.Ifthesepartsareshort-circuitedandtheirfunctionsbecomeineffective,theymay
result in fatal accidents such as a burnout. Avoid short-circuiting and do not use parts not 
recommendedbyOKIDATACorporation.