2
About The Meter
6
METER BUTTONS
SETPTS Button
In the Run Mode, this button will sequentially recall the previous setpoint settings. As
necessary, use the
/NT/GRS and
/TARE buttons to alter these settings, then press
the SETPTS button to store new values.
Unless you press the SETPTS,
/TARE, or
/NT/GRS button within 20 seconds, the
meter will scroll to setpoint 2 and then to the Run Mode.
If the dual relay option is not installed or if L.3=1 is displayed on the LK.CF
menu, pressing the SETPTS button will display the meter's firmware version.
/NT/GRS Button
In the Run Mode, this button will toggle between net/gross readings or peak readings
depending upon setup.
In the Configuration Mode, press this button to change the value of the flashing digit
shown on the display and/or toggle between menu choices, such as R.1=R or R.1=N on
RD.CF menu. When configuring your setpoint values, press the
/NT/GRS button to
advance the flashing digit's value from 0 to 9 by 1.
/TARE Button
In the Run Mode press the
/TARE button to tare your reading (zeroing).
In the Configuration Mode, press the this button to scroll to the next digit.