49
4.9.1 HTTPget using Port 2000 (continued)
*SRDF Get Dewpoint Reading in Fahrenheit from Probe 1
*SRTD2 Get Dewpoint Reading in Fahrenheit from Probe 1
*SRDF3 Get Dewpoint Reading in Fahrenheit from Probe 1 and 2;
separated by a semi-colon
*SRB/*SRBC Get Temperature and Humidity Reading in Celsius from Probe 1;
separated by a semi-colon
*SRB2/*SRBC2 Get Temperature and Humidity Reading in Celsius from Probe 2;
separated by a semi-colon
*SRB3/*SRBC3 Get Temperature and Humidity Reading in Celsius from Probe 1
and 2; separated by a semi-colon
*SRBF Get Temperature and Humidity Reading in Fahrenheit from
Probe 1; separated by a semi-colon
*SRBF2 Get Temperature and Humidity Reading in Fahrenheit from
Probe 2; separated by a semi-colon
*SRBF3 Get Temperature and Humidity Reading in Fahrenheit from
Probe 1 and 2; separated by a semi-colon
*SRYS Indicate AC or DC power and battery status
*SRYRST Reset Power on
*SR_XD1 Disable alarm condition check for relay 1
*SR_XD2 Disable alarm condition check for relay 2
*SR_XC2 Reset relay 2 latch condition
*SR_XC1 Reset relay 1 latch condition
*SR_XC2 Reset relay 2 latch condition
*SR_XE1 Re-enable alarm condition check for relay 1 (must be
executed after *SR_XD1)
*SR_XE2 Re-enable alarm condition check for relay 2 (must be
executed after *SR_XD2)
*SR_XP1 Close relay 1 for < 200 mSec
*SR_XP2 Close relay 2 for < 200 mSec
*SR_XH1 Close relay 1
*SR_XH2 Close relay 2
*SR_XL1 Open relay 1
*SR_XL2 Open relay 2
*SR_XR1 Read current state of relay 1
*SR_XR2 Read current state of relay 2
Commands developed specifically for DASYLab/LabView
*SRAC Get All Readings in below format in Celsius
*SRAF Get All Readings in below format in Fahrenheit
Format:
T1[+/-]###.#H1[+/-]###.#D1[+/-]###.#T2[+/-]###.#H2[+/-]###.#D2[+/]###.#;[EndCharacter]
*SRACS Get All Readings in below format in Celsius
*SRAFS Get All Readings in below format in Fahrenheit
Format:
[+/-]###.# [+/-]###.# [+/-]###.# [+/-]###.# [+/-]###.# [+/-]###.#;[EndCharacter]