4-35
4-2 Function Mode
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
4
Parameter List
I/O terminal function
C160
Input Terminal 1
Response Time
0. to 200. (× 2 ms)
1. no yes
ms 5-32
C161
Input Terminal 2
Response Time
1. no yes
C162
Input Terminal 3
Response Time
1. no yes
C163
Input Terminal 4
Response Time
1. no yes
C164
Input Terminal 5
Response Time
1. no yes
C165
Input Terminal 6
Response Time
1. no yes
C166
Input Terminal 7
Response Time
1. no yes
C169
Multi-step
Speed/Position
Determination
Time
0. to 200. (× 10 ms) 0. no yes ms 5-63
Control parameter
H001
Auto-tuning
Selection
00: Disabled
01: Enabled (motor does not
rotate)
02: Enabled (motor rotates)
00 no no 5-146
H002
Motor Parameter
1
00: Standard motor
parameter
01: Auto-tuning parameter
00 no no
5-145
H202
Motor Parameter
2
00 no no
H003
Motor Capacity 1
0.1/0.2/0.4/0.55/0.75/1.1/1.5/
2.2/3.0/3.7/4.0/5.5/7.5/11.0/
15.0/18.5
Default
setting
no no kW
H203
Motor Capacity 2
Default
setting
no no kW
H004
Motor Pole
Number 1
2/4/6/8/10
4nono
pole
H204
Motor Pole
Number 2
4nono
H005
Speed
Response 1
1. to 1000.
100. yes yes
H205
Speed
Response 2
100. yes yes
Parameter
No.
Function name Monitor or data range
Default
setting
Set data
Data can
be set
during
RUN
Data can be
changed
during RUN
Unit
Page

Table of Contents