EasyManua.ls Logo

Omron 3G3MX2 - 2-Step Acceleration;Deceleration Function (2 CH)

Omron 3G3MX2
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-66
5-6 Operation Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
5
Functions
2-step Acceleration/Deceleration Function (2CH)
The acceleration/deceleration time can be changed during acceleration/deceleration.
Select an acceleration/deceleration time switching method from the following 3:
(1) Switching using a multi-function input terminal
(2) Automatic switching at a desired frequency
(3) Automatic switching together with forward/reverse switching only
To switch via a multi-function input terminal, allocate "09: 2CH" to any of C001 to C007.
Example 1) Switching via Input Terminal (A094/A294 = 00)
Parameter
No.
Function
name
Data
Default
setting
Unit
A092/A292
1st/2nd
Acceleration
Time 2
0.01 to 3600.
(Example 1.2)
10.00
(15.00)
s
A093/A293
1st/2nd
Deceleration
Time 2
0.01 to 3600.
(Example 1.2)
10.00
(15.00)
s
A094/A294
2-step
Acceleration/
Deceleration
Selection
00
Switched via 2CH terminal (example 1)
00
01
Switching via 2-step acceleration/deceleration
frequency (example 2)
02
Enabled only when switching between forward/
reverse (example 3)
A095/A295
2-step
Acceleration
Frequency
0.00 to 400.0 (1000.)
Enabled when 2-step Acceleration/Deceleration
Selection (A094/A294) is 01 (example 2)
0.00 Hz
A096/A296
2-step
Deceleration
Frequency
0.00 to 400.0 (1000.)
Enabled when 2-step Acceleration/Deceleration
Selection (A094/A294) is 01 (example 2)
0.00 Hz
C001 to C007
Multi-function
Input Selection
09: 2CH (2-step acceleration/deceleration)
−−
Related functions F002/F202, F003/F203
FW input
2CH input
Output frequency
Acceleration
time 1
Deceleration
time 2
Acceleration
time 2
Deceleration
time 1
F002/
F202
A092/
A292
A093/
A293
F003/
F203

Table of Contents