EasyManua.ls Logo

Omron 3G3MX2 - Frequency Arrival Signal (FA1 to FA5)

Omron 3G3MX2
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-122
5-9 Functions Relating to Protections, Warnings and Various Output Signals
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
5
Functions
Frequency Arrival Signal (FA1 to FA5)
When the output frequency reaches the set level, a frequency arrival signal is output.
Allocate "01: FA1 (constant speed reached)," "02: FA2 (set frequency min. reached)," "06: FA3
(set frequency only)," "24: FA4 (set frequency min. reached 2)," or "25: FA5 (set frequency only
2)" to any Multi-function Output Terminal Selections (C021 to C022) or Multi-function Relay
Output Function Selection (C026).
Below is the hysteresis of the frequency arrival signal:
ON : (Set frequency) (1% of the maximum frequency) [Hz]
OFF : (Set frequency) (2% of the maximum frequency) [Hz]
If "06: FA3" or "25: FA5" is set, however, operation during acceleration is:
ON : (Set frequency) (1% of the maximum frequency) [Hz]
OFF : (Set frequency) (2% of the maximum frequency) [Hz]
During deceleration
ON : (Set frequency) + (1% of the maximum frequency) [Hz]
OFF : (Set frequency) (2% of the maximum frequency) [Hz]
Parameter
No.
Function name Data
Default
setting
Unit
C042/C045
Arrival Frequency
During
Acceleration/
Arrival Frequency
During
Acceleration 2
0.0
Does not output arrival signal during
acceleration.
0.00 Hz
0.01 to 400.0 (1000.)
Outputs arrival signal during
acceleration.
C043/C046
Arrival Frequency
During
Deceleration/
Arrival Frequency
During
Deceleration 2
0.0
Does not output arrival signal during
deceleration.
0.00 Hz
0.01 to 400.0 (1000.)
Outputs arrival signal during
deceleration.
C021 to C022
C026
Multi-function
Output Terminal
Selection
Multi-function
Relay Output
Function Selection
01: FA1 (Constant speed reached)
−−
02: FA2 (Set frequency min. reached)
06: FA3 Set frequency only)
24: FA4 (Set frequency min. reached 2)
25: FA5 (Set frequency only 2)