EasyManua.ls Logo

Omron 3G3MX2 - Page 240

Omron 3G3MX2
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-123
5-9 Functions Relating to Protections, Warnings and Various Output Signals
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
5
Functions
Constant speed reached (01: FA1)
This signal is output when the frequency reaches the level set by Frequency Setting (F001,
A020, A220) or any of Multi-step Speed References 1 to 15 (A021 to A035).
fon: 1% of the maximum frequency
foff: 2% of the maximum frequency
Example) Maximum frequency fmax = 120 (Hz)
Set frequency fset = 60 (Hz)
fon = 120 × 0.01 = 1.2 (Hz)
foff = 120 × 0.02 = 2.4 (Hz)
During acceleration: ON at 60 1.2 = 58.8 (Hz)
During deceleration: OFF at 60 × 2.4 = 57.6 (Hz)
Set frequency min. reached (02: FA2, 24: FA4)
This signal is output when the frequency exceeds the level set by Arrival Frequency During
Acceleration (C042/C045) or Arrival Frequency During Deceleration (C043/C046).
fon: 1% of the maximum frequency
foff: 2% of the maximum frequency
Set frequency only (06: FA3, 25: FA5)
This signal is output only when the frequency corresponds to the level set by Arrival Frequency
During Acceleration (C042/C045) or Arrival Frequency During Deceleration (C043/C046).
fon: 1% of the maximum frequency
foff: 2% of the maximum frequency
Output frequency
FA1 output
Set frequency
f
on
f
off
Set frequency
FA2/FA4 output
f
on
f
off
C042/C045
C043/C046
Output frequency
FA3/FA5 output
f
on
f
off
C042/C045
C043/C046
f
on
f
off