Appendix-1
Appendix-1 Derating Table
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
A
Appendix-1 Derating Table
In the following table, derate the output current according to the graph shown below if any
model denoted by "Derating required" is used in an environment of 40°C or above in ambient
temperature or if multiple Inverters are installed side by side (side-by-side installation). (The
ambient temperature for side-by-side installation is specified as 10 to 40°C.)
Set a derating output current value as electronic thermal (b012/b212). For electronic thermal
level, refer to "Electronic Thermal Function" on page 5-110.
Derating Need Correspondence Table
: Derating required −: Derating not required
The output current need not be derated for models denoted as "Not required" in the above
table. Use each model within the specified/rated ranges.
Rated voltage Model
Required/
Not
required
3-phase 200 VAC 3G3MX2-A2001
3G3MX2-A2002
3G3MX2-A2004
3G3MX2-A2007
3G3MX2-A2015
3G3MX2-A2022
3G3MX2-A2037
3G3MX2-A2055
3G3MX2-A2075
3G3MX2-A2110
3G3MX2-A2150
1-phase 200 V AC 3G3MX2-AB001
3G3MX2-AB002
3G3MX2-AB004
3G3MX2-AB007
3G3MX2-AB015
3G3MX2-AB022
3-phase 400 VAC 3G3MX2-A4004
3G3MX2-A4007
3G3MX2-A4015
3G3MX2-A4022
3G3MX2-A4030
3G3MX2-A4040
3G3MX2-A4055
3G3MX2-A4075
3G3MX2-A4110
3G3MX2-A4150