5-53
5-5 Settings Relating to Control Method
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
5
Functions
When b089 set to 02
The carrier frequency reduction rate is 2 kHz per second.
The upper limit of Carrier Frequency (b083) variable with this function conforms to the set value
of carrier frequency b083, and the lower limit is 3 kHz.
If b083 is 3 kHz or below, this function is disabled regardless of the setting of b089.
15.0kHz
Fin temperature (°C)
Carrier frequency
12.0kHz
9.0kHz
6.0kHz
3.0kHz
50 60 70 8040