12-19
12 Pulse Outputs
CP1E CPU Unit Software User’s Manual(W480)
12-4 Defining Origin Position
12
12-4-2 Flow of Operation
To perform an origin search or to use a Limit Input Signal as an input to a function other than origin
search, set the parameters on the Pulse Output 0 and Pulse Output 1 Tab Pages in the PLC Setup.
12-4-2 Flow of Operation
1
• Set the origin search parameters in the
Pulse Output 0 and Pulse Output 1 Tab
Pages of the PLC Setup using the CX-Pro-
grammer.
2
• Set output pulse 0 or 1, and whether to use
terminals 00 and 01, or 02 and 03 on the
CIO100 terminal block for pulse outputs.
• Output the status of the Limit Signal Inputs
and Positioning Completed Signal to Auxil-
iary Area bits.
• Execute ORG. Specify an origin search.
12-4-3 Settings in PLC Setup
PLC Setup
Ladder
program
Cyclic task,