17 Ethernet Option Board
17-12
CP1E CPU Unit Software User’s Manual(W480)
The Ethernet Option Board can read data from the allocated words in the DM area and CIO area of the
CPU Unit.
• DM area allocation:
Display the initial settings of the Ethernet Option Board using the Web browser function.
• CIO area allocation:
Store the status of the Ethernet Option Board.
Note The initial settings of the Ethernet Option Board cannot be set in the allocated words in the DM area or in the
CX-Programmer’s system settings.
The settings of the Ethernet Option Board can be confirmed by the following two methods.
• Web browser function: Confirm from the Web browser of a computer connected with Ethernet.
• Allocated words in the DM area (D1300 to D1356): The setting values will be read to the CPU Unit
from the Ethernet Option Board when the power is ON. Confirm the PLC memory with the CX-Pro-
grammer.
The status of the Ethernet Option Board can be confirmed by the following two methods.
• Web browser function: Confirm from the Web browser of a computer connected with Ethernet.
• Allocated words in the CIO area (CIO 80 to CIO 82): The status is stored in the CPU Unit from the
Ethernet Option Board every 3 to 5 seconds. It is used for the status confirmation in the ladder pro-
grammer.
17-3-2 Transferring Data from the CPU Unit
Confirmation on the Settings of the Ethernet Option Board
Confirmation on the Status of the Ethernet Option Board
I/O memory
Ethernet
Option Board
CPU Unit
Web browser function
CIO area allocation
80
㨪
82
Internal status
DM area allocation
D1300
㨪
D1454
٨Read the
initial settings
Port㧝(right)
Internal system setup
٨Initial settings
When the power is
ON or the board is
restarted
Each cycle
Ethernet
٨Status
٨Read the
status
Port㧝(right)
IP ADDRESS:
SUBNET MASK:
COMMERR
10BASE-T
100BASE-TX