Appendices
A-70
CP1E CPU Unit Software User’s Manual(W480)
A-2-2 Read/Write Words
Address
Name Function Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
flags,
settings
Words Bits
A500 12 IOM Hold Bit Turn ON this bit to preserve the status
of the I/O Memory when shifting from
PROGRAM to RUN or MONITOR
mode or vice versa.
ON: Retained
OFF: Not retained
Retained Not
retained
Refreshed
when power is
turned ON.
13 Forced Status Hold
Bit
Turn ON this bit to preserve the status
of bits that have been force-set or
force-reset when shifting from PRO-
GRAM to MONITOR mode or vice
versa. Always use this bit together with
the IOM Hold Bit (A500.12), i.e., turn
them ON at the same time.
ON: Retained
OFF: Not retained
Retained Not
retained
Refreshed
when power is
turned ON.
14 Error Log Reset Bit Turn this bit ON to reset the Error Log
Pointer (A300) to 00.
Note 1 The contents of the Error Log
Area itself (A100 to A199) are
not cleared.
2 This bit is automatically reset
to 0 after the Error Log Pointer
is reset.
OFF to ON: Clear Retained Cleared A100 to
A199,
A300
15 Output OFF Bit Turn this bit ON to turn OFF all outputs
from the CPU Unit, CP-series Expan-
sion Units, and CP-series Expansion
I/O Units. The INH indicator on the
front of the CPU Unit will light while
this bit is ON.
Note This bit is cleared when the
power supply is turned OFF.
Retained Cleared
A508 09 Differentiate Monitor
Completed Flag
ON when the differentiate monitor con-
dition has been established during
execution of differentiation monitoring.
Note This flag will be cleared to 0
when differentiation monitoring
starts.
ON: Monitor condi-
tion established
OFF: Not yet estab-
lished
Retained Cleared
A510
to
A511
(CP1E
N/NA-
type
CPU
Unit
only)
− Startup Time These words contain the time at which
the power was turned ON. The con-
tents are updated every time that the
power is turned ON. The data is stored
in BCD.
A510.00 to A510.07: Second (00 to
59)
A510.08 to A510.15: Minute (00 to 59)
A511.00 to A511.07: Hour (00 to 23)
A511.08 to A511.15: Day of month (01
to 31)
Note 1 The data will be unstable if the
capacitor becomes
discharged.
2 In an E-type CPU Unit, or if
the clock data is not set for an
N/NA-type CPU Unit, the data
will be for 1:01.01 on Sunday
January 1, 2001.
See Function col-
umn.
Retained See
Function
column.
Refreshed
when power is
turned ON.