Variable name _EIP_TDLinkOpnErr
Meaning Tag Data Link Connection Failed Global/local Global
Function NX-series CPU Units: Indicates that establishing a tag data link connection for CIP communications 1 failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
• The information registered for a target node in the tag data link parameters is dif
ferent from the actual node
information.
• There was no response from the remote node.
FALSE: Other than the above.
NJ-series CPU Units: Indicates that establishing a tag data link connection failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
• The information registered for a target node in the tag data link parameters is different from the actual node
information.
• There was no response from the remote node.
FALSE: Other than the above.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user pro-
gram
Possible. Related in-
structions
---
Variable name _EIP1_TDLinkOpnErr
Meaning CIP Communications1 Tag Data Link Connec-
tion Failed
Global/local Global
Function Indicates that establishing a tag data link connection for CIP communications 1 failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
• The information registered for a target node in the tag data link parameters is dif
ferent from the actual node
information.
• There was no response from the remote node.
FALSE: Other than the above.
Note You can use this system-defined variable only for NX-series CPU Units.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user pro-
gram
Possible. Related in-
structions
---
Variable name _EIP2_TDLinkOpnErr
Meaning CIP Communications2 Tag Data Link Connec-
tion Failed
Global/local Global
Function Indicates that establishing a tag data link connection for CIP communications 2 failed.
TRUE: Establishing a tag data link connection failed due to one of the following causes.
• The information registered for a target node in the tag data link parameters is dif
ferent from the actual node
information.
• There was no response from the remote node.
FALSE: Other than the above.
Note You can use this system-defined variable only for the NX701 CPU Units and NX102 CPU Units.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user pro-
gram
Possible. Related in-
structions
---
3 System-defined Variables Related to the Built-in EtherNet/IP Port
3-47
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
3-3 Specifications for Individual System-defined Varia-
bles
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX102-12 Series and is the answer not in the manual?

Omron NX102-12 Series Specifications

General IconGeneral
BrandOmron
ModelNX102-12 Series
CategoryController
LanguageEnglish

Related product manuals