Variable name _EIP_TDLinkErr
Meaning Tag Data Link Communications Error Global/local Global
Function NX-series CPU Units: Indicates that a timeout occurred in a tag data link connection for CIP communications 1.
TRUE: A timeout occurred.
F
ALSE: Other than the above.
NJ-series CPU Units: Indicates that a timeout occurred in a tag data link connection.
TRUE: A timeout occurred.
FALSE: Other than the above.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user pro-
gram
Possible. Related in-
structions
---
Variable name _EIP1_TDLinkErr
Meaning CIP Communications1 Tag Data Link Communi-
cations Error
Global/local Global
Function Indicates that a timeout occurred in a tag data link connection for CIP communications 1.
TRUE: A timeout occurred.
F
ALSE: Other than the above.
Note You can use this system-defined variable only for NX-series CPU Units.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user pro-
gram
Possible. Related in-
structions
---
Variable name _EIP2_TDLinkErr
Meaning CIP Communications2 Tag Data Link Communi-
cations Error
Global/local Global
Function Indicates that a timeout occurred in a tag data link connection for CIP communications 2.
TRUE: A timeout occurred.
F
ALSE: Other than the above.
Note You can use this system-defined variable only for the NX701 CPU Units and NX102 CPU Units.
Data type BOOL Range of values TRUE or FALSE
R/W access R Retained Not retained. Network Publish Published.
Usage in user pro-
gram
Possible. Related in-
structions
---
3 System-defined Variables Related to the Built-in EtherNet/IP Port
3-48
NJ/NX-series CPU Unit Built-in EtherNet/IP Port Users Manual (W506)

Table of Contents