NOTE:
In order to help the Auto-level part to function, make sure to use the same
suction caps for A and B channels and set the arms to be symmetrical.
When any of the VG grippers is used without a HEX-E/H QC but used on an E-series controller
the following extra option becomes available:
Seek: when checked, the same seeking action will happen as above. Since the auto leveling
part is not used the VG grippers need to be parallel to the surface.
NOTE:
Setting a lower vacuum gives a faster grip with less wear on the vacuum cups.
It also reduces the risk of leaving suction marks on delicate workpieces.
It can take a few seconds when pressing Play or Test before the robot program
starts. This is normal.
When the two channels are set to dierent vacuum percentages the VG
grippers automatically release air into the channel with lower pressure. This
feature is activated when the pressure is more than 20% vacuum over the
setting. Releasing air generates a characteristic rumbling sound and change in
pumping speed.
VG Release
This command is used to release the grip of the workpiece by removing vacuum.
OPERATION