EasyManua.ls Logo

Optimus DC-600ETH - Sending a Warning Message to Zones or Groups; Sending an Evacuation Message to Zones or Groups; Display of Busy Zones; Information about Busy Zones, Unavailable Zones and Zone Errors, after Sending an Announcement or Message

Optimus DC-600ETH
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC-600ETH version 1.4
32
Control central and
paging desk
DC-600ETH
If you have configured the desk enabling the option
Emergency mode at buttons (see section 7.2.2),
when WARNING or EVACUATION is pressed, the desk
automatically goes into emergency mode and plays
the message to the emergency group, regardless of
the zone selected.
In zone selection mode, the messages assigned to the
WARNING and EVACUATION buttons are not available
when these messages are selected from the keypad.
If you do not know the identifier of the
message, press OK and a list with the name
of each message and its identifier will appear.
Use the navigation keys / to locate the
pre-recorded message that you require and
press OK.
To delete, use the DEL key.
4. Press the PLAY key.
If you wish to stop the message before it
ends, press the PLAY key.
5. Once the message has ended, press the
navigation key to return to the start screen.
11.2.5. Sending a Warning message to
zones or groups
1. Using the numeric keypad, enter the identifier
numbers of the zone or group where you wish
to send the message.
If you do not know the identifier number
corresponding to a zone or group, follow
points 1) and 2) in section 11.2.3.
To delete, use the DEL key.
2. Press the WARNING key.
The message is repeated until the WARNING
key is pressed once again.
3. Press the navigation key to return to the
start screen.
11.2.6. Sending an Evacuation
message to zones or groups
1. Using the numeric keypad, enter the identifier
numbers of the zone or group where you wish
to send the message.
If you do not know the identifier number
corresponding to a zone or group, follow
points 1) and 2) in section 11.2.3.
To delete, use the DEL key.
2. Press the EVACUATION key.
The message is played indefinitely until the
EVACUATION key is pressed once again.
The evacuation message takes priority over
the warning message. If the evacuation
message is activated while the warning
message is being played, the warning
message will stop.
3. Press the navigation key to return to the
start screen.
11.2.7. Display of busy zones
It is possible to view a list of busy zones (the
zones must belong to the same PA Area as the
desk or the desk must belong to a Global PA
Area).
1. From the start menu, press .
2. The list of busy zones appears. You can
navigate through the list by means of the
and keys.
The list shows the name of the busy zone and
the mode (priority level) of the source
occupying that zone.
3. Press the navigation key to return to the
start screen.
11.2.8. Information about busy zones,
unavailable zones and zone errors, after
sending an announcement or message
Once an announcement has been sent, if it has
not been possible to broadcast this in any of the
zones or groups selected, a list appears of the
zones in which an incident has occurred,
classifying the incident as follows:
Busy: Zones in which it has not been possible
to play the announcement because an
announcement of higher priority is being
played.
Unavailable: The zones or groups do not
exist or access to these zones or groups from
the desk is restricted.
Zones error: Zones in which it has not been
possible to play the announcement.
Use the and keys to move from one list to
another.
Press OK to return to the start screen.

Table of Contents