Replace a Storage Shelf Power Supply
44 Oracle Database Appliance Service Manual • February 2016
Callout Description
1 Fan fail indicator
2 AC power fail indicator
3 Power supply status indicator
4 DC power fail indicator
5 On/Off switch
6 AC connector
If any of the LEDs [1 - 4] are amber, or if the power supply status indicator does not light,
replace the power supply.
1.
Ensure the power supply on/off switch is in the "O" off position.
2.
Disconnect the power cord tie strap from the power cord, and unplug the power
cord from the power supply.