Install a Fan Module
Chapter3 • Servicing CRUs That Do Not Require System Power Off 57
The fan release lever engages when the fan is fully seated.
3.
Verify that the Fan Fault Status LED on the replacement fan module is lit green.
4.
Verify that the following fault LEDs on the applicable server node are off.
■
Front and rear Service Required LEDs located on the applicable server node
■
REAR HDD/PS/FAN LED located on the front of the applicable server node
See “Server Node Status Indicators” on page 17 for more information about system LEDs.
Servicing Power Supplies (CRU)
Oracle Database Appliance (original version) is equipped with two hot swappable power
supplies. They are redundant, meaning that the system can operate with a single power supply.
This allows you to remove and replace a power supply without shutting the system down.
If a power supply fails and you do not have a replacement available, to ensure proper airflow,
leave the failed power supply installed in the system.