39
MEXE02
Internal I/O monitor
All I/O signals of the driver and the hall sensor signal detected in the driver can be monitored.
Signals not assigned to direct I/O can also be checked.
Alarm monitor
The alarm history of the driver can be monitored.
z
Items that can be checked in the alarm history
Item Description
Code This is a code to represent the content of the generated alarm.
Alarm message This is the content of the generated alarm.
Driver temperature This is the driver temperature when an alarm was generated.
Inverter voltage This is the internal voltage of the driver when an alarm was generated.
Selection number This is the operation data number selected when an alarm was generated.
Load factor This is the load factor when an alarm was generated.
Command speed This is the command speed when an alarm was generated.
Actual speed This is the actual speed when an alarm was generated.
Elapsed time from BOOT
This is the elapsed time until an alarm was generated from when the power was turned
on.
Elapsed time from starting operation This is the elapsed time until an alarm was generated from the start of operation.
Main power supply time
This is the cumulative elapsed time until an alarm was generated from when the main
power supply was rst time turned on.
Physical input This is the input status of the D-IN0 to D-IN5 when an alarm was generated.
Physical output This is the input status of the DOUT0 to DOUT3 when an alarm was generated.
Internal I/O This is the internal status of I/O signals when an alarm was generated.
Sub code This is our code for checking.
When the sensor error at power-on and the EEPROM error shortly after power-on are generated, "0" is shown in all elds.
(Excluding the code, alarm message, and main power supply time)
Information monitor
Information of the driver can be monitored.