Operation
35
DTX-2200-3000 AC/DC
5B) BALANCING the
AMPLITUDE
of the
CURRENT
(I) (-50-+20) It is possible to adjust the amplitude of the current
(I) while the electrode stays in place independently, using positive or negative values, guaranteeing perfect
control of penetration and cleanliness, drastically reducing side incisions.
Display
- +
-50 150% 50%
Display
- +
0 100% 100%
Display
- +
+20 80% 120%
Press the
BALANCING
and
FREQUENCY
(T4) key once, wait a few
seconds,
and hold the same key down for at
least 2 seconds. Then use the ENCODER Knob (E) to adjust the value shown on the DISPLAY (D).
LED L30 flashing intermittently.
To exit, simply push the BALANCING and
FREQUENCY
(T4) key again (BALANCING LED off).