Operation
51
DTX-2200-3000 AC/DC
L11 - L21 1
st
LEVEL PEAK CURRENT I
1p
2200 AC/DC 3000 AC/DC
5 - 220 A 5 - 300 A
L19 2
nd
LEVEL PEAK CURRENT I
2p
2200 AC/DC 3000 AC/DC
25 - 220 A 25 - 300 A
L20 1
st
LEVEL BASE CURRENT I
1b
2200 AC/DC 3000 AC/DC
5 - 220 A 5 - 300 A
L23 PULSATION FREQUENCY
f
2200 AC/DC - 3000 AC/DC
ULTRA FAST 500 - 2000 Hz
To exit the setting phase, hold the WELDING PARAMETERS SE- LECTION key (T10) down for about 1
second
.
SYN PULSE +
Bi-Level
Press the PULSE key (T5) until the requited pulsation is active (SYN LED on).
Press the WELDING MODE SELECTION key (T9) until the Bi- Level welding mode is active (Bi-Level LED on).
Press the WELDING PARAMETERS SELECTION key (T10) a number of times to set the following (in addition to
the WELDING PARAMETERS defined as being “BASIC”):