Setting and Changing Function
Various function data can be changed and set when the operation is stopped.
Note that some functions can be changed during operation.(See page 35)
Press the STOP button to stop the inverter
Press the SET button to display the parameter
P03 data.(The main display will flicker.)
STOP
SET
0 0
Press the MODE button
r
MODE
F
Setting functions when operation is stopped.
[Setting example: Change the maximum frequency from 50Hz to 60Hz.]
Press the MODE button
r
MODE
d
Press the MODE button(Enter the function
setting mode)
(if a password is set, it must be entered at this
point. See page 53.)
MODE
0P
0P
05
Press the Ʒ(UP)button, and change the data
display value to "60". (The main display will flicker.)
06
Press the SET button to set the data.SET
0P
Press the MODE button to make the
status ready for operation.
MODE
0 0
OPERATION PREPARATION
COMPLETED
…The normal stop state will be entered and
the inverter can be run.
[Setting Precautions]
1ˊAfter the function is set, the inverter will not run unless the MODE button is pressed and
the "operation preparation completed" state is returned to.
2ˊIf the function setting returns to the "operation preparation completed" state during data
changing, while a start input signal is being applied through external control, an "OP"
error will be displayed, causing the inverter to remain inoperative.
Reset the fault indication using the instructions under "Resetting Fault Trips" (page 90).
3ˊThe set data will be stored in the memory even after the power supply has been turned OFF.
(Changing the parameter P03 data from "50" to "60".)
Press the MODE button
MODE
0n
Main display
34
0
0
Press theƷ(UP) button twice, and change the
parameter No. to P03.