EasyManua.ls Logo

Panasonic AAD03011 - Operation Control Status Monitor (R147); Frequency Setting (DT 237 and 238); Operation Control Setting (R250); Fault Reset Command (DT253), Emergency Stop Command (DT255)

Panasonic AAD03011
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Frequency setting(DT 237 and 238)
䊶㩷In order to set frequency with communication control, parameter P09 is set to "6".
䊶㩷
If registor No. 237 is written into the inverter, the memory inside the inverter does not work.
(Turn off the power supply of the inverter, the set data will not be saved.)
䊶㩷If registor No. 238 is written into the inverter, the memory inside the inverter will save it.
Use register No. 237 when frequency is changed frequently.
The inverter cannot be set in faulty case.
䃂㩷Operation control setting(R250ƶ)
䊶㩷When performing the operation control with communication, set parameter P08 to "3".
If the inverter is in faulty case, fault will not reset even operation command is OFF ("0").
Use fault reset command (DT253), if fault reset is required.
R2500 Run command state
R2501
Reverse run command state
1: ON command
0: OFF command
Fault reset command(DT253)
䊶㩷The fault reset activates by writing "0h9696" in the register No.253.
䊶㩷The usable data is "0
h9696" only.
䊶㩷㪫he command is ignored when the inverter is operating properly.
䃂㩷Emergency stop command(DT255)
䊶㩷The emergency stop activates by writing "0h9696" in the register No.255.
䊶㩷The coast-to-stop function is performed displaying "AU" in the same operation as
the auxiliary fault input.
䊶㩷The usable data is "0
h9696" only.
䃂㩷
Operation control status monitor(R147
ƶ
)
It indicates the operation control status of the inverter.
Relay No. Name Details
Relay No. Name Details
R1470 OPEN command state
R1471 CLOSE command state
R1472
OPEN arrival command state
R1473
CLOSE arrival command state
R1474 Safety sensor input state
R1475
OPEN speed change command state
R1476
CLOSE speed change command state
1: With command
0: No command
82

Table of Contents

Related product manuals