䂓 Connected Device, Wire Size and Main Circuit Terminal
Tightening Torque
Note1) If the breaker's overcurrent trip is a magnetic type, the device could overheat
due to higher harmonics. Use a load rate of 50% or less in this case.
Note2) When using an installed circuit breaker with motor protection, remove it.
Inverter capacity Circuit breaker
Wire size
2mm
䌻 14AWG 䌽
2
Tightening torque
1.2 N
䊶
m0.4 kW
BC
䋭
30N 10A
䂓 Wiring (Main Circuit Terminal)
Power
supply
Circuit breaker
(MCCB)
䌌 䌎
䌕 䌖 䌗
Motor
IM
Ground
terminal
Main circuit terminals
Brake resistor
Brake resistor
connection
terminal
䇶 Screw size䇷
Ground marking
Main circuit terminal: M4 Grounding terminal: M4
1When using the regenerative brake, select the one with brakes. The brake
resistor is built in the inverter. (It is built in the radiation fin.)
2When using regenerative brakes, set the parameter P17 data to"0".
The brakes will not activate when the factory setting "1" is set.
3The regenerative brake specifications are shown below. Carefully consider
the working conditions before using these brakes.
Note that the inverter could be damaged if the specifications are exceeded.
䊶Maximum duty factor (%ED): 2%
䂓 Precautions for Using Regenerative Brakes
Note) Always connect protective devices such as fuse for overcurrent, short circuits
and leakage protection to the input terminal.
17
Class D(3) grounding
䊶Maximum working time: 3s
䊶Maximum torque: 100%