EasyManua.ls Logo

Panasonic AAD03011 - Fault on Operation Open Arrival Hold Time (Parameter P71); Repeat Open Arrival Hold Time (Parameter P72); Repeat Close Arrival Hold Time (Parameter P73); S-Shaped Acceleration;Deceleration Function (Parameter P74)

Panasonic AAD03011
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FAULT ON OPERATION OPEN ARRIVAL HOLD TIME (Parameter P71)
Used to set the time of the fault ON operation of obstacle detection from reaching
OPEN arrival position to changing to normal operation.
(See page 73, the "supplementary explanation of obstacle detection function".)
0.0 to 10
0.0 to 10
REPEAT OPEN ARRIVAL HOLD TIME( Parameter P72)
REPEAT CLOSE ARRIVAL HOLDTIME (Parameter P73)
Used to set hold operation time of door control (repeat) when OPEN arrival
and CLOSE arrival.
Till hold time, the rotation direction is reversed.
The selection of door control (repeat) can be set with parameter P09.
S-SHAPED ACCELERATION/DECELERATION FUNCTION (Parameter P74)
The acceleration/deceleration pattern can be selected.
Data setting
Details
Linear acceleration/deceleration (Factory setting data)0
1
S-shaped acceleration/deceleration (Quadratic curve)
2
S-shaped acceleration/deceleration (Cubic curve)
Acceleration
time
Acceleration
time
Frequency
Frequency
Note1) The acceleration/deceleration time is always the same regardless of the acceleration/
deceleration pattern (Linear or S-shaped acceleration/deceleration).
Note2) S-shaped acceleration/deceleration function is applicable to all acceleration/
deceleration operations.
62
Data setting range (s)
Data setting range (s)
Deceleration
time
Quadratic
curve
Cubic
curve
Linear

Table of Contents

Related product manuals