Note1) When the OPEN / CLOSE signals are turned ON by frequency inverter control:
䊶If Parameter P09 is set to "0, 6", operation status will not change. When the
operation stops and the OPEN / CLOSE signals are turned ON simultaneously,
the operation will not be carried out.
Note2) When the OPEN / CLOSE signals are turned ON by door control:
䊶If Parameter P09 is set to "1, 4", operation status will be ON(forward run) operation.
(OPEN is prior.)
Note3) When the OPEN / CLOSE signals are turned OFF by door control:
䊶If Parameter P09 is set to "1, 4", note that the operations are different due to
different door operation area and different parameter setting status.
䊶Continue to operate(hold operation) in OPEN hold area and CLOSE hold area.
Set parameter d42(stop time of hold operation) if stop operation(hold operation)
is required.
䊶Stop carrying out operation in OPEN operation area and CLOSE operation area.
Set Parameter P70 (forced operation time of fault ON operation) and Parameter
P75(stop select in OPEN/CLOSE operation), if stop operation(hold operation)
is not required.
Note4) Rotation direction setting with door control (repeat):
䊶Start: Start the inverter after rotation direction by OPEN or CLOSE signal is set.
䊶In operation: After the OPEN or CLOSE signal is detected, the rotation direction will
switch automatically. (Arrival hold time may be set by Parameter P72 and P73.)
The rotation direction in "dr mode(rotation direction setting mode) "cannot be set
due to the inconsistence between command signal and control status.
OPEN signal
(Terminal No.1)
CLOSE signal
(Terminal No.2)
Nj0njǃNj6nj
Frequency
inverter control
OFF
Parameter setting of Parameter P09
䃂 Precautions on operation control with control terminal(external control)
When Parameter P08 is set to "2", note that the operations are different
due to different settings of P09.
Nj1njǃNj4nj
Door control
(normal)
Nj2njǃNj3njǃNj5nj
Door control (repeat)
Door control (detect)
OFF
ON OFF
OFF ON
ON ON
Stop (Note3) Stop
(Note1)
ON(forward run) operation
OFF(reverse run) operation
ON(forward run)
operation
(Note2)
Operation (Note 4)
䋪Rotation directions
may switch
automatically.
44