EasyManua.ls Logo

Panasonic AAD03011 - 1 St Acceleration Time (Parameter P01); 1 St Deceleration Time (Parameter P02); V;F Pattern (Parameter P03); Functional Descriptions (by Parameters) 41

Panasonic AAD03011
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functional Descriptions (By parameters)
V/F PATTERN (Parameter P03)
A frequency range of 50/60Hz or 50 to 250Hz can be set independently from
the maximum output frequency (50 to 250 Hz).
Data setting
value
5 0
Name
Base frequency=50Hz
6 0
F F
Free mode
Remarks
Output voltag(%)
Output voltag(%)
Output voltag(%)
[50Hz mode] [60Hz mode]
Output frequency 50(Hz) Output frequency 60(Hz) Output frequency(Hz)
[Free mode]
Max. output frequency=50Hz
Base frequency=60Hz
Max. output frequency=60Hz
Max. output frequency
(P14)
Base frequency(P15)
100
0
100
0
100
0
Note1) Both the maximum output frequency and base frequency are set to 50Hz as the
factory setting data.
Note2) Take note to the upper frequency clamp (parameter P29) when changing the
maximum output frequency setting.
1st ACCELERATION TIME (Parameter P01)
Used to set the time to accelerate to the maximum
output frequency from 0.5Hz.
Data setting range (s)
Setting unit (s)
Setting unit (s)
0.04 0.1㩷㫋㫆㩷999
0.10.1 㫋㫆1001100 㫋㫆㩷999
䊶㩷The display code for 0.04s is "000".
䊶㩷The maximum output frequency is set with parameters
P03 and P14.
output frequency
(Hz)
output frequency
(Hz)
Max. output
frequency
0.5
Acceleration
time
Deceleration
time
1st DECELERATION TIME (Parameter P02)
Used to set the time to decelerate from the maximum
output frequency to 0.5Hz.
Data setting range (s)
0.04 0.1 to 999
Max. output
frequency
0.5
41
0.10.1 to1001100 to 999
The display code for 0.04s is "000".
The maximum output frequency is set with parameters
P03 and P14.
50Hz mode
60Hz mode
The V/F pattern is set regardless of the parameter
P14 and P15.
The V/F pattern is set according to the parameter P14 and
P15. The maximum output frequency is set in parameter
P14 and base frequency is set in parameter P15.

Table of Contents