COMMUNICTION PARAMETER(Parameter P35 to P40)
Used to set the parameters necessary for communication.
Parameter
No.
Function name
Communication
station No. setting
P35
Communication speed
1 to 31
48˖4800bps/96˖ 9600bps/192˖19200bps
Data setting value and details
P36
Stop bit 1:1bit / 2:2bitP37
Parity check 0: No parity/ 1: Odd parity/ 2: Even parityP38
Timeover detect (s)P39
Send wait time (ms)
P40
Main display
SET
P 0
P REGION PASSWORD(Parameter 41)
Parameter P41: Sets passwords for the parameters in all regions(P region and d region).
0 0
STOP
MODE
P S
7 7
After this step, the data is changed with the normal changing procedures.
Example when password is set to "777" for parameter P41.
Note) After the password is set, the "function setting mode" cannot appear without
inputing the password.(Write down the password so that you do not forget it.)
54
1 to 999ǂ
0
1
7
Note2) If the hold time for information exchange disabled state exceeds the permitted
time when operation command select(parameter P08) and frequency setting
signal (parameter P09) is being set for communication, the inverter will fault stop
(OP display). The permitted time can be set with timeover detect (parameter P90).
Note1) The power supply must be turned off after setting the data for the communication
parameters P35 to P40. The set values will be effective afer the power supply is
turned on again.
A password can be set to prevent unintentional changes to the parameter
data after they have been set.
Data setting range 000
.
1 to 999( "000" indicates that there is no password.)
[Procedures for changing parameter
data after setting password]
Press the STOP button to stop the inverter.
When the MODE button is pressed five times,
the password input display(P.PS) will appear, and
the main display will flicker.
Press the Ʒ(up) and (down) buttons to display
the previously set password.
(The main display will flicker.)
The parameter No. will appear when the SET button
is pressed.
( Example: When the previous parameter No. is "P01".)
000
.
0.1 to 60( "000" is the setting not to
perform the time-over detect.)
P.

Table of Contents

Related product manuals