d21 DT277
OPEN Arrival hold frequency
˴ 00.5250 Hz 0-25000 3
d22 DT278 CLOSE Frequency 1 00.5250 Hz 0-25000 3
d23 DT279 CLOSE Frequency 2 00.5250 Hz 0-25000 3
d24 DT280 CLOSE Frequency 3 00.5250 Hz 0-25000 3
d25 DT281 CLOSE Frequency 4 00.5250 Hz 0-25000 3
d26 DT282 CLOSE Frequency 5 00.5250 Hz 0-25000 3
d27 DT283 CLOSE Frequency 6 00.5250 Hz 0-25000 3
d28 DT284
OPEN Accel./decel. time 1
00.1999 sec 0-9990 2
d29 DT285
OPEN Accel./decel. time 2
00.1999 sec 0-9990 2
d30 DT286
OPEN Accel./decel. time 3
00.1999 sec 0-9990 2
d31 DT287
OPEN Accel./decel. time 4
00.1999 sec 0-9990 2
d32 DT288
OPEN Accel./decel. time 5
00.1999 sec 0-9990 2
d33 DT289
OPEN Accel./decel. time 6
00.1999 sec 0-9990 2
d34 DT290
CLOSE Accel./decel. time 1
00.1999 sec 0-9990 2
d35 DT291
CLOSE Accel./decel. time 2
00.1999 sec 0-9990 2
d36 DT292
CLOSE Accel./decel. time 3
00.1999 sec 0-9990 2
d37 DT293
CLOSE Accel./decel. time 4
00.1999 sec 0-9990 2
d38 DT294
CLOSE Accel./decel. time 5
00.1999 sec 0-9990 2
d39 DT295
CLOSE Accel./decel. time 6
00.1999 sec 0-9990 2
d40 DT296 OPEN Hold current
0.0100
A 0-1000 2
d41 DT297 CLOSE Hold current 0.0100 A 0-1000 2
d42 DT298
STOP time of OPEN/ CLOSE hold operation
00.1999
sec
0-9990 2
d43 DT299
OPEN arrival hold wait frequency
0.5250 Hz 50-25000 3
d44 DT300
CLOSE arrival hold wait frequency
0.5250 Hz 50-25000 3
d45 DT301
OPEN arrival hold wait time
0.010 sec 0-100 2
d46 DT302
CLOSE arrival hold wait time
0.010 sec 0-100 2
d47 DT303
OPEN start timer (SW mode)
˴ 0.03.0 sec 0-300 3
d48 DT304
OPEN deceleration timer (SW mode)
0.03.0 sec 0-300 3
d49 DT305
CLOSE start timer (SW mode)
0.03.0 sec 0-300 3
d50 DT306
CLOSE deceleration timer (SW mode)
0.03.0 sec 0-300 3
d51 DT307
Operation frequency when
power supply is turned ON
00.5250
Hz
0-25000 3
d52 DT308
Door width measurement frequency
0.5250 Hz 50-25000 3
d53 DT309
Password setting in D region
01999 0-999 1
87
d54 DT310
Fault CLOSE operation frequency 1 (Hz)
00.5250 Hz 0-25000 3
d55 DT311
Fault CLOSE operation frequency 2 (Hz)
00.5250 Hz 0-25000 3
Parameter
No.
Register
No.
Function nam
Displayed
Data
Unit
Internal
Data
Data
type
19 DT275
OPEN Frequency 5
0
0.5
250 Hz 0-25000 3
20 DT276
OPEN Frequency 6
0
0.5
250 Hz 0-25000 3