Web User Interface Reference Enable c=0.0.0.0 Hold (RFC 2543) (Page 110)
SIP_HOLD_ATTRIBUTE_n
Parameter Name Example
SIP_HOLD_ATTRIBUTE_1
Value Format INTEGER
Description Specifies whether to set "a=inactive " or not when the call is on hold.
Value Range
• 0: send only
• 1: inactive
Default Value 0
SDP_USER_ID_n
Parameter Name Example
SDP_USER_ID_1
Value Format STRING
Description Specifies the user ID used in the "o=" line field of SDP.
Value Range Max. 32 characters
Default Value Empty string
TELEVENT_PAYLOAD
Value Format INTEGER
Description Specifies the RFC 2833 payload type for DTMF tones.
Note
• This
setting is available only when "OUTBANDDTMF_n" is set to
"Y".
Value Range 96–127
Default Value 101
Web User Interface Reference Telephone-event Payload Type (Page 112)
HOLD_SOUND_PATH_n
Parameter Name Example
HOLD_SOUND_PATH_1
Value Format INTEGER
Document Version 2015-02 Administrator Guide 223