Value Range Max. 384 characters
Note
If this URL ends with "/" (slash), "Config{mac}.cfg" is
automatically added at the end of the URL. For example,
CFG_STANDARD_FILE_PATH="http:// host/dir/" becomes
CFG_STANDARD_FILE_PATH="http://host/dir/
Config{mac}.cfg".
For details about the formats, see 2.1.3 Server Address
Formats.
Default Value Empty string
Web User Interface Reference Standard File URL
CFG_PRODUCT_FILE_PATH
Value Format STRING
Description Specifies the URL of the product configuration file, which is used
when all units with the same model number need the same settings.
Value Range Max. 384 characters
Note
If this URL ends with "/" (slash), "{MODEL}.cfg" is
automatically added at the end of the URL. For example,
CFG_PRODUCT_FILE_PATH="http://host/ dir/" becomes
CFG_PRODUCT_FILE_PATH="http:// host/dir/{MODEL}.cfg".
For details about the formats, see 2.1.3 Server Address
Formats.
Default Value Empty string
Web User Interface Reference Product File URL
CFG_MASTER_FILE_PATH
Value Format STRING
Description Specifies the URL of the master configuration file, which is used
when all units need the same settings.
Value Range Max. 384 characters
Note
If this URL ends with "/" (slash), "sip.cfg" is automatically
added at the end of the URL. For example,
CFG_MASTER_FILE_PATH="http://host/ dir/" becomes
CFG_MASTER_FILE_PATH="http:// host/dir/sip.cfg".
For details about the formats, see 2.1.3 Server Address
Formats.
Default Value Empty string
Web User Interface Reference Master File URL
5.3.5 Provisioning Settings