CFG_CYCLIC
Value Format BOOLEAN
Description Specifies whether the unit periodically checks for updates of
configuration files.
Value Range
• Y: Enable periodic synchronization
• N: Disable
Default Value
N
Web User Interface Reference Cyclic Auto Resync
CFG_CYCLIC_INTVL
Value Format INTEGER
Description Specifies the interval, in minutes, between periodic checks for
updates of the configuration files.
Value Range 1–40320
Default Value 10080
Web User Interface Reference Resync Interval
CFG_RESYNC_TIME
Value Format STRING
Description Specifies the time (hour:minute) that the unit checks for updates of
configuration files.
Value Range 00:00–23:59
Note
• If the value for this setting is any valid value other than an
empty string, the unit downloads the configuration files at the
fixed time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are disabled.
• If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Default Value Empty string
Web User Interface Reference Time Resync
CFG_RTRY_INTVL
Value Format INTEGER
Description Specifies the period of time, in minutes, that the unit will retry
checking for an update of the configuration files after a configuration
file access error has occurred.
Note
• This setting is available only when "CFG_CYCLIC" is set to "Y".
Value Range 1–1440
5.3.5 Provisioning Settings
182 Administrator Guide Document Version 2016-05