No. SX-DSV02472 -142-
Class 7: Special setting 2
Class No. Title Unit Range
Function / Contents Attribute
Reference
7 40
Station alias setting
(higher
)
— 0-255 2 Top 8 bits of a station alias are defined. R All ―
41 Station alias selection — 0-2 2
Select the setting origin of a station alias.
0:RSW(lower)+Pr7.40(higher)
1:SII
:
R All ―
42
Maximum continuation
communication error
—
-32768
- 32767
2
Set ug the maximum of the number of
times of communication unusual
continuation generating.
bit0-3 : Err80.7 detection
threshold value
bit4-7 : (Reserved)
bit8-11 : (Reserved)
:
R All ―
43 Lost link detection time ms
0-32767
2
An ESM state after Init->PreOP
changes, When either Port0 or Port1
carries out this parameter setup time
progress in the state (Port which is Lost
link removes from an Init->PreOP
changes time) where it was set to Lost
link, Err85.2 "Lost link detection
unusual protection" occurs.
When 0 is set up, detection of Err85.2
"Lost link detection unusual protection"
R All ―
44 Software version —
-2147483648-
2147483647
4
The software versions 1 and 2 of a
product are displayed.
bit 31-28: (Reserved: Permanently set
at 0)
bit 27-16: Software version 1 (in
hexadecimal three-digit notation)
bit 15-12: (Reserved: Permanently set
at 0)
bit 11-0: Software version 2 (in
hexadecimal three-digit notation)
For example, in the case of the software
version 1: 1.23 and software version 2:
4.56, the value of this parameter will be
X All ―
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation