2-4 I/O signal allocation function
Default I/O signal allocation can be changed.
2-4-1 Input signal allocation
Desired input signal can be allocated to any input pin of I/O connector. The logic can be changed.
Some allocation limit is applied to specific signals. Refer to “(2) Reallocation of input signal”.
(1) Using with the default setting
The table below shows default signal allocation.
Note: Default settings of certain model will differ from those shown below. If the default settings shown in Reference
specification SX-DSV02471are different from values shown below, the settings described in SX-DSV02471
are valid default values.
Pin
name
Pin
No.
Applicable
parameter
Default
setting
( ): decimal
notation
Position/
Full-closed control
Velocity control Torque control
SI1 5 Pr 4.00
00323232h
(3289650)
SI-MON5 a-contact SI-MON5 a-contact SI-MON5 a-contact
SI2 7 Pr 4.01
00818181h
(8487297)
POT b-contact POT b-contact POT b-contact
SI3 8 Pr 4.02
00828282h
(8553090)
NOT b-contact NOT b-contact NOT b-contact
SI4 9 Pr 4.03
00222222h
(2236962)
HOME a-contact HOME a-contact HOME a-contact
SI5 10 Pr 4.04
00202020h
(2105376)
EXT1 a-contact EXT1 a-contact EXT1 a-contact
SI6 11 Pr 4.05
00212121h
(2171169)
EXT2 a-contact EXT2 a-contact EXT2 a-contact
SI7 12 Pr 4.06
00303030h
(3158064)
SI-MON3 a-contact SI-MON3 a-contact SI-MON3 a-contact
SI8 13 Pr 4.07
00313131h
(3223857)
SI-MON4 a-contact SI-MON4 a-contact SI-MON4 a-contact
*1) Operation of a-contact and b-contact:
a-contact: The current in the input circuit is shut down and the photocoupler is turned OFF.
— function disabled (OFF state)
The current flows through the input circuit and the photocoupler is turned ON.
— function enabled (ON state)
b-contact: The current in the input circuit is shut down and the photocoupler is turned OFF.
— function enabled (ON state)
The current flows through the input circuit and the photocoupler is turned ON.
— function disabled (OFF state)
For the purpose of this specification, the status of the input signal is defined as ON when the signal activates the
specified function and OFF when the signal deactivates the specified function.