No. SX-DSV02472 -12-
(2) Reallocation of input signal
To change the allocation of input signal, change the following parameters.
Class No.
At-
trib-
ute
*1)
Title Range Unit Function
Latch
correction
function
4 00 C
SI1 input
selection
0
00FFFFFFh
Assign functions to SI1 inputs.
These parameters are presented in hexadecimals.
Hexadecimal presentation is followed by a specif
ic control mode
designation.
0 0 – – – – * * h: position/full-closed control
0 0 – – * * – – h: velocity control
0 0 * * – – – – h: torque control
Replace * * with the function number.
For the function number see the table below. Logical setup is also a
function number.
Example: To make this pin as SI-MON1_a-
contact for position/full
closed control, and as SI-MON2_b-
contact for velocity control, and
as disabled in torque control mode, set to 0000AF2Eh.
Position ... 2Eh Velocity ... AFh Torque ... 00h
4 01 C
SI2 input
selection
0
00FFFFFFh
Assign functions to SI2 inputs.
Setup procedure is the same as described for Pr 4.00.
4 02 C
SI3 input
selection
0
00FFFFFFh
Assign functions to SI3 inputs.
Setup procedure is the same as described for Pr 4.00.
4 03 C
SI4 input
selection
0
00FFFFFFh
Assign functions to SI4 inputs.
Setup procedure is the same as described for Pr 4.00.
4 04 C
SI5 input
selection
0
00FFFFFFh
Assign functions to SI5 inputs.
Setup procedure is the same as described for Pr 4.00.
* This pin has a latch correction function.
4 05 C
SI6 input
selection
0
00FFFFFFh
Assign functions to SI6 inputs.
Setup procedure is the same as described for Pr 4.00.
* This pin has a latch correction function.
4 06 C
SI7 input
selection
0
00FFFFFFh
Assign functions to SI7 inputs.
Setup procedure is the same as described for Pr 4.00.
* This pin has a latch correction function.
4 07 C
SI8 input
selection
0
00FFFFFFh
Assign functions to SI8 inputs.
Setup procedure is the same as described for Pr 4.00.
*1) For parameter attribute. refer to Section 9-1.