Precautions for input signal assignment
Do not setup to a value other than that specified in the table.
The same signal cant be assigned to multiple pins. Otherwise, duplicated assignment will cause Err 33.0 “Input
multiple assignment error 1 protectionor Err 33.1 “Input multiple assignment error 2 protection”.
A signal used in multiple control modes should be assigned to the same pin and the logic should be matched. If not
assigned to the same pin, the Err33.0 “Input duplicate assignment error 1 protectionor Err33.1 “Input duplicate
assignment error 2 protectionoccurs. In case that the logics do not match, Err33.2 “Input function number error 1
protectionor Err33.3 “Input function number error 2 protectionwill occur.
The duplicated assignment of SI-MON1 and EXT1, SI-MON2 and EXT2, SI-MON4 and EX-SON, and SI-MON5
and E-STOP is not allowed. Duplicate assignment will cause Err33.0 “Input duplicate assignment error 1
protectionor Err33.1 “Input duplicate assignment error 2 protection”.
A-CLR can only be set at a-connect. If set at b-connect, then Err33.2 Input function number assignment error 1
protectionor Err33.3 Input function number assignment error 2 protectionwill occur.
EXT1 can be allocated only to SI5, EXT2 only to SI6. Wrong allocation will cause
Err 33.8 Latch input allocation error protection”.
The Err33.8 “Latch input allocation error protection” occurs if HOME is assigned to S16 and S17, POT is assigned
to S15 and S17, and NOT is assigned to S15 and S16.
When latch correction pins (SI5/SI6/SI7) are used, set up is required for all the control modes. If configuration is
made only for 1 or 2 modes, the Err33.8 “Latch input allocation error protection” occurs.
When latch correction pins (SI5/SI6/SI7) are used, only a-contact can be specified. If b-contact is specified, the
Err33.8 “Latch input allocation error protection” occurs.
If a latch correction pin is assigned to the over-travel inhibit input (POT/NOT), a-contact is specified. So, the
over-travel inhibit input does not work when cable is broken. Be sure to secure safety using another method (e.g.
installing a mechanical stopper).
Safety precautions:
The over-travel inhibit input (POT, NOT) and forced alarm input (E-STO
P) should normally be set to
b-contact, which stops when wire is broken.
If a-contact is specified, be sure that there is no safety hazard.
Latch correction
terminal
SI5
SI6
SI7
a
contact
only
Logic
a
contact
only
a
contact
only
Internal
process
Connections to use edge of the sensor signal as home
EXT1
EXT2
EXT3
or
or
HOME
POT
R1.05