EasyManua.ls Logo

Panasonic MINAS-A5B Series - Page 74

Panasonic MINAS-A5B Series
155 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. SX-DSV02472 -68-
Setup value
Switching condition
Gain switching condition
7 Position command exists Valid for position and full-closed controls.
Shift to the 2nd gain when the positional command was not 0 previously with
the 1st gain.
Return to the 1st gain when the positional command was kept 0 previously
during delay time with the 2nd gain.
8 Not in positioning complete Valid for position and full-closed controls.
Shift to the 2nd gain when the positioning was not completed previously with
the 1st gain.
Return to the 1st gain when the positioning was kept in completed condition
previously during delay time with the 2nd gain.
9 Actual speed is large Valid for position and full-closed controls.
Shift to the 2nd gain when the absolute value of the actual speed exceeded (level
+ hysteresis) (r/min) previously with the 1st gain.
Return to the 1st gain when the absolute value of the actual speed was kept
below (level -hysteresis) (r/min) previously during delay time with the 2nd gain.
10 Position command exists +
Actual speed
Valid for position and full-closed controls.
Shift to the 2nd gain when the positional command was not 0 previously with
the 1st gain.
Return to the 1st gain when the positional command was kept at 0 during the
delay time and the absolute value of actual speed was kept below
(levelhysteresis ) (r/min) previously with the 2nd gain.
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation