No. SX-DSV02472 -75-
Class No.
At-
trib-
Title Range Unit Function
2 18 B
3rd damping
frequency
0–2000 0.1 Hz
You can set up the 3rd damping frequency of the damping control which
suppresses vibration at the load edge. The driver measures vibration at
load edge. Setup unit is 0.1 [Hz]
The setup frequency is 1.0 to 200.0 [Hz]. Setup of 0 to 9 becomes invalid.
2 19 B
3rd damping
filter setup
0–1000 0.1 Hz
If torque saturation occurs with damping frequency 3rd enabled, decrease
the setup value, or if the operation is slow, increase it. Usually set it to 0.
Note:
The maximum setup value is internally limited to the corresponding
damping frequency or 2000–damping frequency, whichever is smaller.
2 20 B
4th damping
frequency
0–2000 0.1 Hz
You can set up the 4th damping frequency of the damping control which
suppresses vibration at the load edge.
The driver measures vibration at load edge. Setup unit is 0.1 [Hz]
The setup frequency is 1.0 to 200.0 [Hz]. Setup of 0 to 9 becomes invalid.
2 21 B
4th damping
filter setup
0–1000 0.1 Hz
If torque saturation occurs with damping frequency 4th enabled, decrease
the setup value, or if the operation is slow, increase it. Usually set it to 0.
Note:
The maximum setup value is internally limited to the corresponding
damping frequency or 2000–damping frequency, whichever is smaller.
*1) For parameter attribute, refer to Section 9-1.