Loading...
ADJ-2
SECTION 3 ADJUSTMENTS
<RZ31K/RS30K>
1. Adjustment item and procedure
When the following parts are disassembled or replaced, please adjust the items according to the table below.
Adjustment Item Replaced Component Remarks
1.1. Lighting area adjustment Parts in the DMD block, Lighting block
1.2. Convergence adjustment DMD block
1.3. EEPROM data transfer [ A] - P. C . B o a r d
Transfer the data from old [A]-P.C.Board to new
one
1.4. Lens calibration
Lens mounter, Stepping motor, [A]-
P.C. B o a r d
Turn off during operating the lens shift or focus.
Move the lens by manual. Not necessary when
the item "1.3. EEPROM data transfer" was taken.
1.5. Model information setup [A] - P.C. B o a r d
Not necessary when the item "1.3. EEPROM data
transfer" was taken
1.6. Clog sensor calibration [A]-P.C.Board / [M2]-P.C.Board
1.7. Date and time setup [A ] - P.C . B o a r d
1.8. LD unit runtime reset LD unit
1.9. LD unit error information
reset
Take this procedure to clear the error information
saved in the memory. (Runtime is not reset)