470 SEQ.SCAN SETUP
SEQ.SCAN : ON OFF
DWELL TIME : ..S (02S-30S)
RESTART TIME: ..0S (010S-300S)
↑↓←→
:MOVE ESC:PRV
Alarm Memory Method Setup [480]
The following procedures are only available when the AV Codec is set to TRANSMITTER in the [100 MODE] menu.
This menu lets you set the alarm storage method in the codec at the remote site when an alarm is received from an associated
alarm sensor.
480 VIDEO MEMORY
ALARM MEMORY: PRE/POST PRE ONLY
←→:
SELECT ESC:PRV
1
Move the cursor to the SEQ. SCAN parameter.
Then select either ON or OFF by pressing the
Direction buttons.
ON: Enables sequential scan.
OFF: Disables sequential scan.
2
Move the cursor to the DWELL TIME
parameter. Then enter a specific time by
pressing the numeric buttons.
This item lets you set the length of time that is monitored at
each view point.
It can be specified from 2 to 30 seconds in 1-second incre-
ments.
3
Move the cursor to the RESTART TIME
parameter. Then enter a specific time by
pressing the numeric buttons.
This item lets you set the restart time to return to sequential
scan when a view point is manually controlled during a
scan.
It can be specified from 10 to 300 seconds in 10-second
increments.
* Pre and Post frame
A pre-frame is a frame stored in the memory during stand-
by state or prior to input of the alarm.
A post-frame is a frame stored in memory after an alarm
input.
1
Move the cursor to the ALARM MEMORY
parameter. Then select either mode by
pressing the Direction buttons.
PRE/POST: Enables storage of pre and post frames (video
and audio).
About 20-seconds of pre-frames and 20-seconds of
post-frames can be stored.
PRE ONLY: Enables storage of about 40-seconds of pre
frames only (video and audio).
Storage pre and post frames
When PRE/POST is set for this item, no alarm dialing
takes place till the alarm storage is over after the alarm
input.
Sequential Scan Setup [470]
The following procedures are only available when the AV Codec is set to TRANSMITTER in the [100 MODE] menu.
This menu lets you enable or disable sequential monitoring of view points (1 to 8) at the remote site. This function is available
in a standby state and during communication.
Transmitter
Storage Time
The storage time differs between 30-seconds and 40-
seconds depending on the movement or intricacy of
the objects.
Similarly it may be less than 20-seconds for pre and
post frames.