KENR6933 35
Troubleshooting Section
i02527577
Customer Specied
Parameters Table
Table 32
Customer Specied Parameters
ECM Parameter
Possible Values
Default Value
Engine Rating Parameter
“Rating Number”
1to4 1
Low/High Idle Parameters
“Low Idle Speed” 700 to 1200 rpm 750 rpm
“High Idle Speed” 1900 to 2900 rpm 2650 rpm
ECM Identication Parameter
“Equipment I
D” 17 Digits
Available characters are dependent on
the service tool that is used
Not Programmed
PTO and Throt
tle Lock Parameters
“Throttle Lock Feature Installation
Status”
Installed
Not Installed
Not Installed
“PTO Engine Speed Setting”
0 to 3000 rpm 0 rpm
“Throttle Lock Increment Speed Ramp
Rate”
0 to 600 rpm/sec 400 rpm/sec
“Throttle L
ock Engine Set Speed
Increment”
0 to 200 rpm 10 rpm
Miscellaneous
“Monitoring Mode Shutdowns” Disabled
Enabled
Disabled
“Monitoring Mode D erates”
Disabled
Enabled
Enabled
“Limp Home Desired Engine Speed
700 to 1800 rpm 1200 rpm
J1939 Continuous Fault Handling
“Remote Torque Speed Control Enable
Status”
Disabled
Enabled
Disabled
Congurable Inputs
“Coolant Level Sensor” Not Instal
led
Installed
Not Instal
led
“Air Filter Restriction Sw itch Installation
Status”
Not Installed
Installed
Not Installed
“Fuel/Water Separator Switch
Installation Status”
Not Installed
Installed
Not Installed
“User Dened Switch Installation Status”
Not Installed
Installed
Not Installed