32 KENR6933
Troubleshooting Section
Custom er Specied
Parameters
i02517248
Customer Specied
Parameters
Customer specied parameters allow the engine to
be congured to the exact needs of the application.
Customer parameters may be changed repeatedly as
a customer’s operation changes.
The following information is a brief description of
the customer specied parameters. The following
parameter values are included with the descriptions:
Minimum
Maximum
Default
Engine Rating Parameter
Rating Number
The rating number is the selected rating within a
power rating family. The ash le denes the power
rating family. The ash le can contain one to four
ratings. The rating number denes the power rating
that is used within the power rating family.
Table 16
Minimum Maximum Default
141
Low/High Idle Parameter s
Low Idle Speed
The Low Idle Speed” is the minimum engine rpm.
Table 17
Minimum Maximum Default
700 rpm 1200 rpm 750 rpm
High Idle S
peed
The “High Idle Speed” is the maximum engine rpm.
Table 18
Minimum Maximum
Default
1900 rpm 2900 rpm 2650 rpm
ECM Identication Parameter
Equipment ID
“Equipment ID” is the identication of the equipment
that is assigned by the customer. The “Equipment
ID” is only for reference only by the customer. The
“Equipment ID” is not required by the Electronic
Control Module (ECM).
Table 19
Value Default
17 digits
The available characters
are dependent on the
service tool that is
being used.
Not programmed
PTO and Throttle Lock Parameters
Throttle Lock Feature Installation Status
The “Throttle Lock Feature Installation Status” is
used to turn on the throttle lock features. When
this parameter is changed to “Installed”, the “PTO
engine Speed Setting”, the “Throttle Lock Increment
Speed Ramp Rate and the “Throttle Lock Engine
Set Speed Increment” parameters are active and the
parameters can be programmed.
Table 20
Value
Default
Not Installed
Installed
Not Installed
PTO Engine Speed Setting
The “PTO Engine Speed Setting is the engine speed
that is attained when the PTO switch is moved to
the ON position. If the PTO Engine Speed Setting”
parameter is programmed, the feature is turned off.
If the “PTO Engine Speed Setting” parameter is set
to a value that is between “1” and the low idle speed,
the parameter is set to the low idle speed value. If
the PTO Engine Speed Setting” parameter is set to
a value that is higher than the high idle speed, the
parameter is set to the high idle speed value.