(Table 8, contd)
3226-12
Aftertreatment #1 Outlet NOx :
Failure
3609-12
Aftertreatment #1 Outlet #1 NOx Level
Sensor : Failure
Troubleshooting, “Sensor (Data Link Type) - Test”
3242-3
Aftertreatment #1 DPF Intake Gas
Temperature : Voltage Above Normal
2452-3
DPF #1 Intake Temperature Sensor :
Voltage Above Normal
Troubleshooting, “Sensor Signal (Analog, Passive) - Test”
3242-4
Aftertreatment #1 DPF Intake Gas
Temperature : Voltage Below Normal
2452-4
DPF #1 Intake Temperature Sensor :
Voltage Below Normal
Troubleshooting, “Sensor Signal (Analog, Passive) - Test”
3358-3
Engine Exhaust Gas Recirculation
Inlet Pressure : Voltage Above
Normal
3385-3
EGR Intake Pressure Sensor : Voltage
Above Normal
Troubleshooting, “Sensor Signal (Analog, Active) - Test”
3358-4
Engine Exhaust Gas Recirculation
Inlet Pressure : Voltage Below
Normal
3385-4
EGR Intake Pressure Sensor : Voltage
Below Normal
Troubleshooting, “Sensor Signal (Analog, Active) - Test”
3358-13
Engine Exhaust Gas Recirculation
Inlet Pressure : Out of Calibration
3385-13
EGR Intake Pressure Sensor : Out of
Calibration
Troubleshooting, “Sensor Calibration Required - Test”
3360-3
Aftertreatment #1 DEF Controller :
Voltage Above Normal
3820-3
Aftertreatment #1 Diesel Exhaust Fluid
Controller : Voltage Above Normal
Troubleshooting, “Electrical Power Supply - Test”
3360-4
Aftertreatment #1 DEF Controller :
Voltage Below Normal
3820-4
Aftertreatment #1 Diesel Exhaust Fluid
Controller : Voltage Below Normal
Troubleshooting, “Electrical Power Supply - Test”
3360-9
Aftertreatment #1 DEF Controller :
Abnormal Update Rate
3820-9
Aftertreatment #1 Diesel Exhaust Fluid
Controller : Abnormal Update Rate
Troubleshooting, “CAN Data Link - Test”
3360-14
Aftertreatment #1 DEF Controller :
Special Instruction
3820-14
Aftertreatment #1 Diesel Exhaust Fluid
Controller : Special Instruction
Troubleshooting, “Data link Configuration Status - Test”
3361-5
Aftertreatment #1 DEF Dosing Unit :
Current Below Normal
3821-5
Aftertreatment #1 Diesel Exhaust Fluid
Dosing Valve Actuator : Current Below
Normal
Troubleshooting, “Solenoid Valve - Test (Solenoid Valves that
Connect to the Dosing Control Unit (DCU))”
3361-6
Aftertreatment #1 DEF Dosing Unit :
Current Above Normal
3821-6
Aftertreatment #1 Diesel Exhaust Fluid
Dosing Valve Actuator : Current Above
Normal
Troubleshooting, “Solenoid Valve - Test (Solenoid Valves that
Connect to the Dosing Control Unit (DCU))”
3363-5
Aftertreatment #1 DEF Tank Heater :
Current Below Normal
3126-5
Aftertreatment #1 DEF Tank #1 Heater
Coolant Diverter Solenoid : Current Be-
low Normal
Troubleshooting, “Solenoid Valve - Test (Solenoid Valves that
Connect to the Dosing Control Unit (DCU))”
3363-6
Aftertreatment #1 DEF Tank Heater :
Current Above Normal
3126-6
Aftertreatment #1 DEF Tank #1 Heater
Coolant Diverter Solenoid : Current
Above Normal
Troubleshooting, “Solenoid Valve - Test (Solenoid Valves that
Connect to the Dosing Control Unit (DCU))”
3509-3
Sensor Supply Voltage 1 : Voltage
Above Normal
262-3
5 Volt Sensor DC Power Supply : Volt-
age Above Normal
Troubleshooting, “Sensor Supply - Test”
(continued)
38 UENR4469-36
Diagnostic Trouble Codes
Copyright of Perkins Engine Company Limited. NOT FOR REPRINTING OR RESALE