(Table 9, contd)
3619-11
Aftertreatment #1 Outlet #1 NOx Lev-
el Sensor Power Supply : Other Fail-
ure Mode
5759-11
Aftertreatment #1 Outlet Gas Sensor
Power Supply : Other Failure Mode
Troubleshooting, “Electrical Power Supply - Test”
3621-11
Engine Exhaust NOx Level Sensor
Power Supply : Other Failure Mode
5758-11
Aftertreatment #1 Intake Gas Sensor
Power Supply : Other Failure Mode
Troubleshooting, “Electrical Power Supply - Test”
3666-5
Engine Fuel Supply Lift Pump Relay :
Current Below Normal
1075-5
Engine Electric Lift Pump for Engine
Fuel Supply : Current Below Normal
Troubleshooting, “Fuel Transfer Pump - Test”
3666-6
Engine Fuel Supply Lift Pump Relay :
Current Above Normal
1075-6
Engine Electric Lift Pump for Engine
Fuel Supply : Current Above Normal
Troubleshooting, “Fuel Transfer Pump - Test”
3820-3
Aftertreatment #1 Diesel Exhaust Flu-
id Controller : Voltage Above Normal
3360-3
Aftertreatment #1 DEF Controller :
Voltage Above Normal
Troubleshooting, “Electrical Power Supply - Test”
3820-4
Aftertreatment #1 Diesel Exhaust Flu-
id Controller : Voltage Below Normal
3360-4
Aftertreatment #1 DEF Controller :
Voltage Below Normal
Troubleshooting, “Electrical Power Supply - Test”
3820-9
Aftertreatment #1 Diesel Exhaust Flu-
id Controller : Abnormal Update Rate
3360-9
Aftertreatment #1 DEF Controller :
Abnormal Update Rate
Troubleshooting, “CAN Data Link - Test”
3820-14
Aftertreatment #1 Diesel Exhaust Flu-
id Controller : Special Instruction
3360-14
Aftertreatment #1 DEF Controller :
Special Instruction
Troubleshooting, “Data Link Configuration Status - Test”
3821-5
Aftertreatment #1 Diesel Exhaust Flu-
id Dosing Valve Actuator : Current Be-
low Normal
3361-5
Aftertreatment #1 DEF Dosing Unit :
Current Below Normal
Troubleshooting, “Solenoid Valve - Test (Solenoid Valves that
Connect to the Dosing Control Unit (DCU))”
3821-6
Aftertreatment #1 Diesel Exhaust Flu-
id Dosing Valve Actuator : Current
Above Normal
3361-6
Aftertreatment #1 DEF Dosing Unit :
Current Above Normal
Troubleshooting, “Solenoid Valve - Test (Solenoid Valves that
Connect to the Dosing Control Unit (DCU))”
3838-5
Aftertreatment #1 Diesel Exhaust Flu-
id Dosing Control Module Relay : Cur-
rent Below Normal
5965-5
Aftertreatment #1 DEF Control Mod-
ule Relay Control : Current Below
Normal
Troubleshooting, “Relay - Test (Aftertreatment Power Relay)”
3838-6
Aftertreatment #1 Diesel Exhaust Flu-
id Dosing Control Module Relay : Cur-
rent Above Normal
5965-6
Aftertreatment #1 DEF Control Mod-
ule Relay Control : Current Above
Normal
Troubleshooting, “Relay - Test (Aftertreatment Power Relay)”
3956-3
Aftertreatment #1 Diesel Oxidation
Catalyst Intake Gas Temperature
Sensor : Voltage Above Normal
4765-3
Aftertreatment #1 Diesel Oxidation
Catalyst Intake Gas Temperature :
Voltage Above Normal
Troubleshooting, “Sensor Signal (Analog, Passive) - Test”
3956-4
Aftertreatment #1 Diesel Oxidation
Catalyst Intake Gas Temperature
Sensor : Voltage Below Normal
4765-4
Aftertreatment #1 Diesel Oxidation
Catalyst Intake Gas Temperature :
Voltage Below Normal
Troubleshooting, “Sensor Signal (Analog, Passive) - Test”
3965-5
Aftertreatment #1 Diesel Exhaust Flu-
id Control Module Power Supply #1 :
Current Below Normal
5966-5
Aftertreatment #1 DEF Control Mod-
ule Power Supply : Current Below
Normal
Troubleshooting, “DEF Control Module Power - Test”
(continued)